Fig. 6
4. Lift up and pull away to remove.
5. Reverse procedure to install.
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Fan Cover
1. Remove racks.
2. Lift fan cover up and out of oven.
Fan Cover Removal
3. Reverse procedure to install.
CONTROL PANEL COMPONENTS
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Removable Components
1. Remove the CONTROL PANEL.
2. Remove the component being replaced.
3. Reverse the procedure to install the replacement
component, then check oven for proper
operation.
COMPONENT PANEL
COMPONENTS
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Removable Components
1. Remove the RIGHT SIDE - FRONT PANEL.
NOTE: If right side panel is not accessible, this
component can be serviced by removing the
CONTROL PANEL.
2. Disconnect the wire leads to the component
being replaced.
3. Remove the component.
4. Reverse the procedure to install the replacement
component and check oven for proper operation.
TEMPERATURE PROBE
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1. Remove the RIGHT SIDE - FRONT PANEL.
NOTE: If right side - front panel is not accessible, this
component can be serviced by removing the
CONTROL PANEL.
Disconnect the probe leads from the solid state
temperature control.
VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - REMOVAL AND REPLACEMENT PARTS
Page 7 of 31 F45534 (0415)