– 14 –
PROGRAMMING MEMORY
Up to 99 Cooking Programs with up to 5 Phases in each program can be keyed-in and stored in
Memory. Each program is accessed by its identifying number. Program numbers range from 00 – 98.
A pre-defined Clean Cycle Deliming program is also available, see page 34.
If the numbered Program has not been programmed (or is vacant), the Time displays – h – – min. No
Mode or Phase indicator lights are lit. The Temperature displays – – or the current temperature.
To C
REATE a new program —
With — — in the program number display, the control is in Manual mode.
Press the key. Program Number 00 is displayed and the control is
in Program Mode. Use UP or DOWN arrows to increase or decrease the
program number until a vacant program number is found.
ENTER THE COOKING INSTRUCTIONS (FOLLOW STEPS 1 – 6):
1) Select the cooking mode: Hot Air, Steam, or Combi.
If Hot Air, select Vent (Closed or Open).
If Combi, set Steam Factor.
2) Set either the Time or Probe Temperature.
3) Set the Oven Temperature or
. Select Fan
1
/2 speed or full.
4) End of the 1st Phase. Press
to shift to the next phase.
5) Repeat steps 1 – 4 for as many of the 5 phases as are needed. Review
the program by stepping through the phases. Make any needed changes.
6) When the program is set, save it in memory by pressing
until the
beep is heard.
NOTE: A cooking program can also be entered in manual mode and saved to a
program number by selecting the Program Number and pressing
for about
three seconds.
To D
ELETE an existing program —
With — — in the program number display, the control is in Manual mode.
Press the
key. Program Number 0 0 is displayed and the control is
in Program Mode. Use UP or DOWN arrows to increase or decrease the
program number until the program number to be deleted is displayed.
Press
and hold it in for about three seconds until the beep sounds,
indicating the program has been deleted.
NOTE: If a previous program had been selected and was active in manual mode,
it will be copied to the selected program number, replacing the previous program.
Verify that the program number is vacant after you delete it.
— —
0 0
— —
0 0