Vulcan-Hart VCE6H ML-126177, VCE10H ML-126178, VCE10F ML-126179, VCE20H ML-126172, VCE20F ML-126173 Convection Oven User Manual


 
35
If the cavity temperature is above 212°F, automatic Cool Down will occur.
During automatic Cool Down, the Time Display will show the rain symbol
instead of time.
The timer will start counting down.
The steam generator will fill with water until the water level controls shut
off the fill.
The steam generator heater elements will produce steam for 30 minutes.
After 30 minutes, the steam generator tank will drain.
The Time Display will show 10 minutes. The timer will not count down.
The Steam Generator will fill and drain two times. The fill time is
programmed for each model.
The Time Display will begin counting down, the Steam Generator heaters
are ON with steam being generated.
At the end of the ten minute interval, the Steam Generator tank will drain.
'DONE' will display in the Temperature Display indicating that the Clean
Cycle is complete.
NOTE: If an error occurs during the Clean Cycle, 'FAIL' will display in the
Temperature Display instead of 'DONE'.
Per the instructions in the filter cartridge replacement and preventive
maintenance kit: Retest the water, return the response card and replace
the filter cartridge.