Vulcan-Hart VCE6H ML-126177, VCE10H ML-126178, VCE10F ML-126179, VCE20H ML-126172, VCE20F ML-126173 Convection Oven User Manual


 
24
EXAMPLE PROGRAM
This example shows how to program a three-phase process for cooking Roast Beef, 18 pounds per
roast, and store it as program number 20.
The second item in the table on page 21 provides most of the information: For Combi time, Phase 2,
15 minutes-per-pound times 18 pounds-per-roast equals 270 minutes (or 4 hours and 30 minutes). We
assumed that Steam Factor at 20 would be OK. We chose the average temperature when a
temperature range was given. We chose to leave the Vent Closed during phase 3. In this example,
we will not use the temperature probe. Refer to the menu card example at the bottom of page 25.
Phase 1 Phase 2 Phase 3
STEAM Mode
212 °F
20 minutes
COMBI Mode - Steam Factor = 20
295 °F
4 hours and 30 minutes
HOT AIR Mode - Vent Closed
375 °F
10 minutes
Turn the oven ON.
Phase 1 Select Steam Mode by pressing
. The first light blinks on the phase button
to indicate you are programming Phase 1. Press : The Temperature displays
212°F and needs no adjustment. Press
and press to increase or to
decrease until the Time displays [
h 20 min ]. Press to shift to Phase 2: The
second indicator light begins to flash.
Phase 2 Select Combi Mode - Steam Factor of 20 by pressing
3 times. The first
three indicator lights will be lit indicating Steam Factor equals 20. Press
and
press
to increase or to decrease until the Temperature displays 295°F.
Press
and press to increase or to decrease until the Time displays
[ 4
h 30 min ]. Press to shift to Phase 3: The third indicator light begins to flash.
Phase 3 Select Convection
(HOT AIR) Mode by pressing once (Vent is Closed). Press
and press to increase or to decrease until the Temperature displays
375°F. Press
and press to increase or to decrease until the Time
displays [
h 10 min ].
Press
twice.
Save Press the
key and press to increase or to decrease until the
Program Number displays
. Verify that this program number is vacant, or
choose a different program number that is vacant. A vacant program displays the
current temperature, blank Time [
h min ], and no Mode or Phase indicator lights
are lit. Then press
until the beep is heard and the program is saved in memory.