A SERVICE OF

logo

- 15 -
(13) Timing Chart
c When receiving normal data:
One of two types of timing for BUSY-ACK can be selected.
(1) Timing 1 (Default)
(2) Timing 2
Data 1 ~ 8
(Host Printer)
nStrobe
(Host Printer)
Busy
(Host Printer)
nAck
(Host Printer)
Approx. 0.7 µsec
Min. 1 µsec
Min. 1 µsec
Min. 1 µsec
Min. 0.5 µsec
Data 1 ~ 8
(Host Printer)
nStrobe
(Host Printer)
Busy
(Host Printer)
nAck
(Host Printer)
Approx. 5 µsec