![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/e6/8e6ca90c-ae05-4b17-9775-95898c601969/8e6ca90c-ae05-4b17-9775-95898c601969-bg60.png)
- 92 -
~ In the case of MaxiCode (Two-dimensional code)
Format c [ESC] XBaa; bbbb, cccc, d (, e) (, Jffgg) (, Zh) [LF] [NUL]
Term aa: Bar code number
00 to 31
bbbb: Print origin of X-coordinate of the bar code
Fixed as 4 digits (in 0.1 mm units)
cccc: Print origin of Y-coordinate of the bar code
4 or 5 digits (in 0.1 mm units)
d: Type of bar code
Z: MaxiCode (Two-dimensional code)
e: Mode selection (Omissible)
Omitted: Mode 2
0: Mode 2
1: Mode 4
2: Mode 2
3: Mode 3
4: Mode 4
5: Mode 2
6: Mode 6
7: Mode 2
8: Mode 2
9: Mode 2
Jffgg: Connection setting (Omissible. No connection if this parameter is omitted.)
ff: Code number 01 to 08
gg: No. of divided codes 01 to 08
Zh: Attachment of Zipper block and Contrast block
(Omissible. If omitted, they are not attached.)
h= 0: No attachment of Zipper block and Contrast block
1: Attachment of Zipper block and Contrast block
2: Attachment of Zipper block
3: Attachment of Contrast block