A3 RS2320006 Rev. 0
CONNECT
ELECTRICAL
CORD
To place electrical receptacle, see
Electrical Receptacle Location
diagram in this manual.
2
3-wire or 4-wire Plug Connection
Four-wire cord is required for mobile homes or where codes (Canada) do
not permit grounding through neutral.
1. Remove access cover from rear of range.
2. Use a strain relief (not supplied) and insert end of power cord (not
supplied) through power supply hole.
3. 4-wire Plug OnlyRemove the green ground screw from range back.
Remove both the hex nuts and the grounding strap from the center
terminal. Position grounding strap down and away from terminal block.
Replace 1 hex nut on the center terminal. Attach the power cord
ground wire (green or bare) and grounding strap to rear bulkhead using
ground screw.
4. Unscrew and use top hex nut to attach the power cord wires to the
terminal block as follows:
Red wire to L1 terminal.
Black wire to L2 terminal.
White wire to Neutral terminal.
5. Tighten all hex nuts and reinstall access cover removed in step 1.
6WUDLQUHOLHI
QRWVXSSOLHGZLWKUDQJH
$FFHVV
FRYHU
ZLUH&RUG,QVWDOOHGZLUH&RUG,QVWDOOHG
/
:KLWH
1HXWUDO
*URXQG
ZLUH
%ODFN
/
5HG
*URXQG
VFUHZ
*URXQG
VWUDS
/
:KLWH
1HXWUDO
%ODFN
/
5HG
Converting 3-Wire to 4-Wire Power Cord
1. Remove access cover from rear of range.
2. Remove bottom strain relief screw and retain for further use.
3. Remove hex nuts from terminal block and retain for further use.
4. Remove all 3-wire or cable leads from the terminal block and proceed to
remove the power cord from the range by pulling in a downward motion
so the cord is removed from strain relief.
5. To install the 4-wire cord, follow the 4-wire instructions shown above.
Range has been grounded at the factory to the center (nickel plated)
terminal of the terminal block in accordance with the National Electric Code.
When a separate ground is required by local code, disconnect the grounding
strap from the terminal block. Ground frame by connecting a grounding wire
to range frame using the grounding strap and screw, as shown below,
removed from the grounding strap.