Amana RS2320006 Oven User Manual


 
Genesis Control Testing Information
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires it.
RS2320006 Rev. 0 C2
Mylar OverlayKRC
OVEN
PREHEAT LOCKED
PUSH TO TURN
BAKE
OVEN
CLEAN
OFF
WM
BROIL
LIGHT
TIMER
ON OFF
COOK
CLEAN
TIME
START
COOK
CLEAN
OVEN TEMP
CLOCK
RECALL
Illustration Component Test Procedure Results
PIN 1
E4
E2
E1
J2
J1
E5
E7
E3
Genesis electronic
range control
On power-up lock
light will blink for
approximately 25
seconds, while
control is verifying
lock latch position.
On power up, if
sensor has failed.
No FCode will be
displayed.
No oven functions
will start.
Measure voltage at terminals
J2E7 (L1) and E2 (NEU)................
Relay drive requirements
BakeBA to L2...............................
Broil BR to L2...............................
Bake...............................................
Broil................................................
Clean
Stage 1...........................................
Stage 2...........................................
Time (Adjustable) ...........................
Failure codes:
F1-Control malfunction .....................
F2-Oven over temperature ...............
F3-Oven temperature sensor
Open or Shorted..........................
F9-Door latch circuit malfunction ......
Temperature Calibration.................
120 VAC should be indicated, verifying
voltage to control.
240 VAC, if not replace control.
240 VAC, if not replace control.
75% bake element 25% broil element
100% broil element
Time controlled 60 minutes 100% broil
50% bake element and 50% broil element
2 hours minimum to 4 hours maximum
Verify voltage to control.
If no voltage is present, check wiring.
If voltage is present, replace control.
Check sensor resistance and wiring.
Replace control if sensor and wiring are
good.
Check sensor resistance and wiring.
Replace sensor, if wiring is good.
Check latch switch and associated wiring.
Turn oven control to OFF position.
Press and hold both slew pads for 5 sec.
Use slew pads to adjust temp setting.
After 5 sec. of no input the mode is exited.