ELECTRICALCONNECTION
The appliance shall be connected toa single
phase electric line rated at 120/208Vac or
120/240Vacand60Hzfrequency.
Electricpowerrating:
‐120/208Vac:2400Wattor12.0Amax.
‐120/240Vac:3100Wattor13.5Amax.
Heatingelementspowerrating:
‐Ovenbakeelement=1600Watt
‐Ovencircular
element=2800Watt
‐Ovendoublebroilelement=1200+1800Watt
Installa suitableelectricpowersupplyreceptacle
connectiontype NEMA1450Rableto supporta
loadofatleast 16A (perline)accordingto local
coderequirements.Forfourorthreewirespower
supplyconnectionsystemsee
diagrambelow.
FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
THREE-WIRE CONN.RECEPTACLE NEMA 14-50R
Checkyour localcode forwhichof theoptions
belowshould be usedin grounding the
receptaclepowersupplyconnections.
OPTION 1 – FOUR Wires connection:
‐ Connect the L1 receptacle terminal to the
incomingBLACK electricalsupplywire(L1hot
wire)
‐ Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2hot
wire)
‐ Connect the NEUTRAL receptacle terminal to
the incoming NEUTRAL (WHITE) electrical
supplywire
‐ Connect the GROUND receptacle terminal to
the incoming GROUND (GREEN) electrical
supplywire
OPTION 2 - THREE-Wires connection:
‐ Connect the L1 receptacle terminal to the
incomingBLACK electricalsupplywire(L1hot
wire)
‐ Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2hot
wire)
‐ Connect the NEUTRAL with the GROUND
receptacleterminal tothe incomingNEUTRAL
(WHITE)electricalsupplywire
DO NOT USE EXTENSION CORDS WITH THIS
APPLIANCE AS IT MAY RESULT IN FIRE,
ELECTRIC SHOCK OR OTHER type of
PERSONAL INJURY.
Theapplianceisequipped atthe factorywith an
electric supply cord set 4 wires type with ring
terminals(L1, L2,N, Ground)suitable forrange
useUL/CSA listedtype SRDT/DRT2x6AWG(L1,
L2)+2x8AWG (N,G) rated 300V, 40 or 50Awith
fused plug typeNEMA1450P; cablelength 1,5
m.;incasethesupplycordsetmustbereplaced,
itshallbereplacedwithanidenticalset having
the same technical specs and followingcarefully
theinstructionsanddiagramsbelow:
1) Disconnect appliance from electrical power
supplyreceptacle
2) Slideouttheappliancefrominstallationplace
toaccessto
backenclosurepanel
3) Remove back enclosure panel by removing
the6screwsasshownbelow
4) Loose strain relief byunscrewing the two
strainrelief'sscrewsasindiagram.