Bertazzoni MAS304DFMXE Range User Manual


 
22
GASBURNERSDATATABLES
Burner Position Injector Gas Pressure MaxRate MinRate Bypass
diam.[mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam.[mm]
Auxiliary RearL 0,92 NG 4” 3750 1098 900 264 Regulated
0,56 LP(Propane) 11” 3750 1098 900 264 0,29
SemiRapid FrontR 1,17 NG 4” 6000 1759 1500 439 Regulated
0,73 LP(Propane) 11” 6300 1845 1500 439 0,36
Rapid RearR 1,55 NG 4” 10400 3046 2500 732 Regulated
0,98 LP(Propane) 11” 11400 3339 2500 732 0,47
FrontLInner 0,80 NG 4” 2730 799 900 264 Regulated
DualBurner 0,50 LP(Propane) 11” 2900 849 900 264 0,29
FrontLOuter N°2x1,30 NG 4” 15000 4394 4500 1318 Regulated
N°2x0,83 LP(Propane) 11” 16400 4804 4500 1318 0,65