This appliance shall only be installed by an
authorizedprofessional.
This appliance shall be installed in accordance
withthemanufacturer’sinstallationinstructions.
This appliance must be installed in accordance
withthenorms&standardsofthecountrywhere
it will be installed. The installation of this
appliance must conform to local
codes and
ordinances. In the absence of local codes,
InstallationsmustconformstoAmericanNational
Standards,NationalFuelGasCodeANSIZ223.1
latestedition**orB149.1.
The appliance, when installed, must be
electrically grounded in accordance with local
codesor,in theabsenceoflocal codes,with the
National
ElectricalCode,ANSI/NFPA70.
Iflocal codespermit, a flexiblemetal appliance
connectionwith thenewAGAorCGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended for connecting this appliance to
the gas supplyline. Do notbend ordamage the
flexibleconnectorwhenmovingthe
appliance.
Thisappliancemustbe usedwiththepressure
regulator provided. The regulator shall be
properlyinstalledinordertobeaccessiblewhen
theapplianceisinstalledinitsfinallocation.The
pressureregulatormustbesetforthetypeofgas
tobeused.Thepressureregulatorhas½”
female
pipe thread. The appropriate fitting must be
determinedbasedonthe sizeofyourgas supply
line,theflexiblemetalconnectorandtheshutoff
valve.
The appliance must be isolated from the gas
supply piping system by closing its individual
manualshutoffvalveduring anypressuretesting
ofthegas
supplypipingsystemattestpressures
equaltoorlessthan½psi(3.5kPa).
Allopeningandholes inthewall andfloor, back
andunder theapplianceshall besealedbefore
installationoftheappliance.
Amanualvalveshallbeinstalledinan accessible
locationin thegas
lineexternal tothe appliance
forthepurposeofturning onor shuttingoff gas
totheappliance
totheappliance
WARNING:Thisapplianceshallnotbeinstalled
with a ventilation system that air downward
towardtherange/rangetop/cooktop;thistypeof
ventilation system may cause ignition and
combustion problem with the
gas cooking
appliance resulting in a personal injury or
unintendedoperation.
WARNING: an air curtain or other overhead
range/rangetop/cooktop hood, which operates
by blowing a downward airflow onto a
range/rangetop/cooktop, shall not be
used/installed in conju nction with this gas
range/rangetop/cooktop.
WARNING!
Donotuseaerosolspraysinthevicinity
ofthis
appliancewhileitisinoperation
ROOM VENTILATION: An exhaust fan may be
used with the appliance; ineach caseit shall be
installed in conformity with the appropriate
national and local standards. Exhaust hood
operationmayaffectotherventedappliances;in
each caseit shallbe installedin
conformitywith
theappropriatenationalandlocalstandards.
TYPEOFGAS
Thisapplianceisshippedfromthefactoryforuse
with natural gas. Foruse with propane LP gas
please follow the conversion procedure
describedon pg.17.Astepbystep conversion
procedureisalsoincludedwitheachset
ofLPgas
nozzles.
GASPRESSURE
Themaximuminletgassupplypressureincoming
to the gas appliance pressure regulator is 20’’
watercolumn(5kPa).
Theminimu mgassupply pressureforchecking
theregulatorsettingshallbeatleast1“w.c.(249
Pa)abovetheinletspecifiedmanifoldpressure
to
the appliance (this operating pressure is 4” w.c.
(1.00kPa)forNaturalGasand11”w.c.(2.75kPa
forLPGas).