20
PRESSUREREGULATOR
Since service pressure may fluctuate with local
demand, every gas cooking appliance must be
equipped with a pressure regulator on the
incoming service line for safe and efficient
operation.
The pressure regulator shipped with the
appliance has two female threads ½” NPT. The
regulatorshallbeinstalledproperly
inordertobe
accessible when the appliance is installed in its
finalposition.
Manifoldpressureshouldbecheckedwitha
manometerandcomplywiththevaluesindicated
below:
Naturalgas4.0"W.c.P.
LP/Propane11.0"W.C.P.
Incominglinepressureupstreamfromthe
regulatormustbe1"W.c.P.higherthanthe
manifoldpressureinordertocheckthe
regulator.
Theregulatorusedon
thisrangecanwithstanda
maximuminputpressureof1/2PSI(14.0"W.c.P.)
Ifthelinepressureexceedsthatamount,astep‐
downregulatorisrequired.
The appliance, its individual shut‐off valve, and
the pressure regulator must be disconnected
from the gas line during any pressure testing of
that system
at pressures in excess of 1/2 psig
(3.45kPa).
The individual manual shut‐off valve must be in
the OFF position during any pressure testing of
the gas supply piping system at test pressures
equaltoorlessthan½psig(3.45kPa).
GASCONVERSION
WARNING!
Beforecarryingoutthisoperation,disconnect
theappliancefromgasandelectricity.
Gasconversionshallbeconductedbyafactory‐
trainedprofessional.
Callthecustomerservicehotlinetoidentifya
factory‐trainedprofessionalnearyourhome.
The gas conversion procedure for this range
includes6steps:
1. Pressureregulator
2.
Surfaceburners
3. Adjustmentofminimumsetting
The conversion is not completed if all 6 steps
havenotbeenconcludedproperly.
Beforeperformingthegas conversion,locatethe
package containing the replacement nozzle
shipped with every range. IMPORTANT: Each
nozzlehasa numberindicatingitsflowdiameter
printedonthe
body.Consultthetableonpage20
formatchingnozzlestoburners.
Savethenozzlesremovedfromtherangefor
futureuse.
STEP1:PRESSUREREGULATOR
Thepressureregulatorsuppliedwiththe
applianceisaconvertibletypepressure regulator
forusewithNaturalGasatanominaloutlet
pressureof
4”w.c.orLPgasatanominaloutlet
pressureof11”w.c.anditispre‐arrangedfrom
thefactorytooperatewithoneofthese
gas/pressureasindicatedinthelabelsaffixedon
theappliance,packageandInstructionbooklet.
Toconverttheregulatorforusewithotherliquid
propaneLPgas:
1. Unscrewbyhandtheuppercapofthe
regulator,removethewhiteplastic
attachmentfromthecap,reverseits
directionandscrewitagainfirmlyagainstthe
cap.Thewhiteplasticattachmenthasarrows
indicatingthepositionfornaturalgas(NAT)
andLPgas(LP).
2. Screw
byhandthemetalcapintheoriginal
positionontheregulator.