Location:
The limit thermostat is located inside the hood on
the tank lid just to the left of the tank heater.
Test Procedure:
1. Disconnect the brewer from the power supply.
2. Disconnect both black wires from the limit ther-
mostat.
3. Check for continuity across the limit thermostat
terminals with a ohmmeter.
If continuity is present as described, reconnect the
black wires to the limit thermostat , the limit thermo-
stat is operating properly.
If continuity is not present as described, press the
reset button on the limit thermostat and repeat step
#3.
After repeating step #3 and no continuity is shown,
replace the limit thermostat.
FIG. 8 LIMIT THERMOSTAT
22978.0000