Bunn Single TF Coffeemaker User Manual


 
Page 20
CONTROL THERMOSTAT
Location:
The control thermostat is located inside the
lower left front of the brewer on the component
bracket.
1. Disconnect the brewer from the power source.
2. Locate the blue wires on the control thermostat.
3. Check the voltage across the blue wires on the
control thermostat and the white insert on the two
or three pole 120V, 120/208V, 120/240V terminal
block and the red insert on two pole 200V or 240V
terminal blocks with a voltmeter. Connect the
brewer to the power source. The indication must
be:
a.) 120 volts ac for two wire 120 volt models, three
wire 120/208 volt models and three wire 120/240
volt models.
b.) 200 to 240 volts ac for two wire 200 or 240 volt
models.
4. Disconnect the brewer from the power source.
P999