Page 9
Problem
Brew cycle will not start (cont.)
Automatic refill will not operate
Remedy
(A) Direction of flow arrow must be
pointing towards brewer.
(B) Remove the strainer/flow con-
trol and check for obstructions. Clear
or replace.
Refer to
Service
- ON/OFF switch for
testing procedures. See page 31
Refer to
Service -
Start switch for
testing procedures. See page 35
Refer to
Service -
Timer for testing
procedures. See page 38 or 40
Refer to
Service -
Dispense valve for
testing procedures. See page 22
Refer to
Service
- Electronic con-
trols for testing procedures. See
pages 23 thru 27
Refer to
Service
- Brew selector
switch for testing procedures. See
page 16
Refer to
Service
- Server sensor for
testing procedures. See page 33
Check plumbing and shut-off valves.
(A) Direction of flow arrow must be
pointing towards brewer.
(B) Remove the strainer/flow con-
trol and check for obstructions. Clear
or replace.
Probable Cause
3. Water strainer/flow control (.500
GPM)
4. ON/OFF switch
5. Start switch
6. Timer
7. Dispense Valve
8. Control Assembly (Electronic)
9. Brew selector switch
10. Server sensor
1. No water
2. Water strainer/flow control (.500
GPM)
TROUBLESHOOTING (cont.)
27118 100400