Bunn Single TF Coffeemaker User Manual


 
Page 21
7. Using a #8-32 slotted head screw fasten the con-
trol thermostat to the component bracket.
8. Refer to the illustration below when reconnecting
the wires.
9. Adjust the control thermostat as required.
NOTE - The capillary tube must be clear of any electri-
cal termination and not kinked.
P842
SERVICE (cont.)
Removal and Replacement:
1. Remove wires from the control thermostat.
2. Remove the thermostat capillary bulb by firmly
pulling-up on the capillary tube at the tank lid. This
will disengage the grommet from tank lid.
3. Remove the #8-32 slotted head screw holding the
control thermostat to the component bracket.
4. Slide the grommet to the line 7" above the bulb on
the new capillary tube.
5. Insert the capillary bulb through the hole in the
tank lid and press the grommet firmly and evenly
so that the groove in the grommet fits into the tank
lid.
6. Carefully bend the capillary tube so that the tube
and bulb inside the tank are in the vertical position.
CONTROL THERMOSTAT (cont.)