Cabletron Systems FRX4000 Water Dispenser User Manual


 
Trap Messages 3-9
Configuring the Trap Table
Link Disabled 401
The port has been disabled from the On-Line Port Operations menu.
Severity Major (Level 2)
Link Disconnected 402
For X.25, this means that the link is disconnected and level 2 cannot be
established.
For SNA TPAD, this means that an XID command frame has been issued by the
TPAD, but either there has been no response or the received XID data does not
match the XID data conÞgured for the TPAD subscriber.
For SNA HPAD, this means that no XID or SNRM command frame has been
received for any link address conÞgured for the HPAD subscriber.
Severity Major (Level 2)
Action Check the hardware at both ends to make sure the devices are
operational and cables are securely connected. For SNA, also
check the conÞguration records to make sure they match the
HPAD/TPAD.
Link Up 403
The level 2 link is up.
Severity Major (Level 2)
X.25 Link Failed 404
The link has failed; some modem controls are not present, and the physical link is
down.
Severity Major (Level 2)
Action Check the modem and cables for secure connections and proper
operation.
Restart with cc “n” dc “n” 405
A Restart has been issued, with the cause code (cc) and diagnostic code (dc)
shown.
Severity Informational (Level 4)
Action Depends on the cause. If necessary, contact your service
representative.