Cabletron Systems FRX4000 Water Dispenser User Manual


 
Configuring the Trap Table
3-22 Trap Messages
Exit Service Affecting Condition 533
The situation that caused event 362 has ended.
Severity Major (Level 2)
DLCI “n” Frm Relay PVC Disconnected 534
Self-explanatory.
Severity Informational (Level 4)
DLCI “n” Received Bad Frame 535
Either the DLCI was not conÞgured or the frame was on an unavailable DLCI.
Severity Minor (Level 3)
Action ConÞgure the DLCI or resent the frame.
DLCI “n” No Response to STATUS ENQ 536
There was no response to a status enquiry from the DTE.
Severity Minor (Level 3)
Action Check the status of the DCE.
DLCI “n” Flow Control On 537
Flow control has been implemented on a frame relay port and data is queued.
Severity Minor (Level 3)
DLCI “n” Frame Discarded—Flow Ctl 538
Self-explanatory.
Severity Minor (Level 3)
Action The frame must be resent.
DLCI “n” Line does not exist 539
Self-explanatory.
Severity Minor (Level 3)
Action Check the conÞguration records for the node, LP and port.
DLCI “n” Not Configured 540
Self-explanatory.
Severity Minor (Level 3)
Action ConÞgure the DLCI in the portÕs database record.