Carrier Container Refrigeration Unit Refrigerator User Manual


 
4-3 62-02575-07
4.3.4 Set Date/Time
Set Date/Time is used to set the date and time of the DataReader. It is important for the user to enter the correct date and
time before beginning any operation. When retrieving data files from a Micro-Link 1 Controller, the date and time
information are taken from the extracting device (the DataReader or laptop PC).
To display the current date and time, press
at the menu prompt. Press again to change the date and time. The
date function will appear as Month (MM), Date (DD), Year (YYYY) and Day of the week. Press aft er entering the
correct date and time to confirm the change.
NOTE
Before beginning any operation, ensure that the correct date and time are set in the DataReader. This is impor-
tant as the Micro-Link 1 DataCORDER obtains its time from the DataReader. The Micro-Link 2 and Micro-
Link 2i use internal clocks.
4.3.5 Power Off
Power Off will switch off power to the unit. Select Power Off and press to turn the power off. To pow er off from
the main menu, press and hold down
at least three seconds.
4.3.6 Micro-Link 1/2/2i
The user will be presented with the following menu selections for t he Micro-Link system Controller (not all menu
items are valid for the Micro-Link 1). The first two items are displayed on the LCD with the cursor at the first item. To
see and select the other items on the menu the user can move the cursor with the up and down arrows to the desired
item. To select the desired item, press
.
Extract Data
Command
Display
Figure 4-4. ML2 Menu
a. Extract Data
Extract Data selected from t he main DataReader menu will present the user with another menu of available functions
(see Figure 4-4). The user can select the desired function with
and .
Extract by Trip
Extract by Date
Last 30 Days
Extract all Data
Figure 4-5. Extract Data Menu
1 Extract By Trip-- Valid for ML 2/2i
Allows the user to extract data for the last trip alone, provided a trip marker was set when the l ast trip was initiated. If
no trip marker is found, then the DataReader will prompt the user t o either abort by pressing
or extract all data by
pressing
.
2 Extract By Date -- Valid for ML 2/2i
Allows the user to extract data within specific dates. Upon selecting the menu, the user is required to enter the begin
and the end dates for the data to be extracted.
3 Last 30 Days-- Valid for ML 2/2i
Allows the user to extract the last 30 records of data starting from the current date. Normally one day data will
constitute one record. In case of multiple records for a single day, t he data extracted will only be for the last 30 records.