Cecilware GB-IT Hot Beverage Maker User Manual


 
2
ELECTRICAL SPECIFICATIONS
Model No.
Volts
Phase
Hz
Watts
Number of
Heaters
Amps
Receptacle
Nema No.
Circuit
Breaker
ALL MODELS 120V 1 60 1.8KW 1 15 5-15R 15A
ALL MODELS 120/240V 1 60 3.0KW 1 15 L14-20R** 20A
ALL EXPORT MODELS 220V 1 60 3.0KW 1 15 †† 20A
GB3M-5.5-IT, GB4M-5.5-IT 120/240V 1 60 6.0KW 2 25 L14-30R** 30A
120V, 1.8 KW, 15A, Nema 5-15R standard on all models; 3.0 KW and 6.0 KW, 120/240V units available
** 120/240V, 3 pole, 4 wire grounding type Twist-Plug Receptacle. For 240V units, Use L6-20R or L6-30R, 2 pole, 3 wire Twist-Plug Receptacle.
†† 220V Export Receptacle to be specified where order is placed.
See Electrical Data Label attached to the back of the unit for proper voltages, breaker sizes and electrical outlet requirements for each model number
listed. See wiring diagram in back of manual, for wiring instructions.
UNPACKING INSTRUCTIONS
Carefully unpack the GB Machine and inspect immediately for shipping damage. Your GB Machine was shipped in a carton designed to give it
maximum protection in normal handling. It was thoroughly inspected before leaving the factory. In case of damage, contact the shipper, not
Cecilware.
INSTALLATION INSTRUCTIONS
Water Inlet Connection:
This equipment is to be installed to comply with the applicable Federal, State, or local plumbing codes having jurisdiction. In addition:
1. A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the machine can be moved for
cleaning underneath.
2. An approved back flow prevention device, such as a double check valve to be installed between the machine and the water supply.
The GB beverage dispenser is equipped with a ¼" Flare Water Inlet Fitting which is located on the left side in the back of the base.
HIGHLY RECOMMENDED:
A WATER SHUT-OFF VALVE and A WATER FILTER, preferably a combination Charcoal/Phosphate Filter, to remove odors and inhibit lime
and scale build up in the machine. Note: In areas with extremely hard water, a water softener must be installed in order to prevent a
malfunctioning of the equipment and in order not to void the warranty.
After the machine has been unpacked and placed on a counter, pull out the stainless steel drip tray. It should contain the following:
A Set of 4 Adjustable Leveling Legs & Water Inlet Fitting.
MECHANICAL SPECIFICATIONS
MODEL: WIDTH
in
DEPTH
in
HEIGHT
in
Lb (qty)
TANK
GAL.
BURST
CAPACITY
LIT DISPLAY AREA
(W x H) Sq. in.
SHIPPG
WEIGHT LB.
GB1M-IT 8.5 22 34 8 (1)
2.2 58 (7 x 13) 91 65
GB2M-5.5-IT 8.5 22 34 5.5 (2)
2.2 58 (7 x 13) 91 86
GB3M-5.5-IT 11 22 34 4 (3)
3.2 85 (9½ x 13) 123 100
GB3M-5.5-IT S/S 11 22 34 5.5 (3)
3.2 85 (9½ x 13) 123 100
GB3M-IT-10 LEFT [11.5”W] 11.5 22 34 10 (1) + 5.5 (2)
4.5 112 (12
3
/
8
x 13) 164 110
GB3M-IT-10 RIGHT [11.5”W] 11.5 22 34 10 (1) + 5.5 (2)
4.5 112 (12
3
/
8
x 13) 164 110
GB4M-IT 14.125 22 34 5.5 (4)
4.5 112 (12
3
/
8
x 13) 164 120
GB5M-IT 17.25 22 34 5.5 (5)
4.5 140 (12
3
/
8
x 13) 164 140