Cecilware GB-IT Hot Beverage Maker User Manual


 
8
13. Rinse Warning Status – This parameter determines whether the Rinse Warning Option is turned ON or OFF. If this option is ON the
system generates a Rinse Warning if a Hopper has dispensed and has not been Rinsed for of time greater than that defined by (50 * Rinse
Lockout Time) minutes. For example: If the Rinse Warning Status is ON and the Rinse Lockout Time is 6 Hours then a Rinse Warning will
be generated when a Hopper is not Rinsed for more than (50 * 6 = 300) minutes (5 hours). Generating a Rinse Warning will cause the
audible alarm to sound for two seconds and the Rinse Warning Screen to be displayed for five seconds. The system will then revert back
to normal operation. If the offending Hopper is not rinsed after the first Rinse warning additional Rinse Warnings will be generated every
five minutes until the respective Hopper is rinsed. The default setting for this parameter is OFF.
14. Rinse Lockout Status - This parameter determines whether the Rinse Lockout Option is turned ON or OFF. If this option is ON the
system generates a Rinse Lockout if a Hopper has dispensed and has not been Rinsed for a period of time greater than that defined by the
Rinse Lockout Time. Once a Hopper enters Rinse Lockout the LED’s of the Dispense Keys related to that Hopper will turn OFF thus
indicating that the Hopper will no longer dispense. The default setting for this parameter is OFF.
15. Rinse Lockout Time – This parameter determines the length of time required before entering Rinse Lockout. The minimum Rinse
Lockout Time = 1 hour. The maximum Rinse Lockout Time is 12 hours. The default value for this parameter is 6 hours
.
16. Water Temperature Set Point – This parameter determines the required reservoir tank water temperature. The minimum Water
Temperature Set Point is 140°F. The maximum Water Temperature Set point is 203°F. The default value for this parameter is 190°F
.
17. Low Water Temperature Lockout Status – This parameter determines whether the Low Water Temperature Lockout Option is turned ON
or OFF. If this option is ON the system generates a Low Water Temperature Lockout if the present water temperature is below the value
defined by the Low Water Temperature Lockout Set Point. Once a Hopper enters Low Water Temperature Lockout, all of the Dispense
Key LED’s will turn OFF thus indicating that the system will no longer dispense. The default setting for this parameter is ON
.
18. Low Water Temperature Lockout Set Point – This parameter determines the minimum reservoir tank water temperature allowed before
entering Low Water Temperature Lockout. The minimum Low Water Temperature Lockout Set Point is 125°F. The maximum Low Water
Temperature Lockout Set point is 203°F. The default value for this parameter is 140°F
.
19. Sleep Mode Status – This parameter determines whether the Sleep Mode Option is turned ON or OFF. If this option is ON and the
system has not dispensed for four hours the system will enter Sleep Mode. Once in Sleep Mode the system will reduce the required Water
Temperature to equal that defined by (10°F + Low Water Temperature Lockout Set Point). The default setting for this parameter is
OFF.
20. Hopper Status – This parameter determines the whether a selected Hopper is turned ON or OFF. If a Hopper is ON then the Auger
Motor, Mixer Motor, and Dump Solenoid status checking is enabled and the Hopper is allowed to dispense. If a Hopper is OFF then Auger
Motor, Mixer Motor, and Dump Solenoid status checking is disabled and the LED’s of the Dispense Keys related to that Hopper will turn
OFF thus indicating that the Hopper will no longer dispense. The default setting for this parameter is OFF.
21. Auger Status – This parameter determines whether the Auger Motor of the selected Hopper is turned ON or OFF. If an Auger Motor is
ON then dispenses from the selected Hopper will include powder (product). If an Auger Motor is OFF then dispenses from the selected
Hopper will not include powder (product). This is a temporary parameter and is reset to the default setting at “power-on”. The default
setting for this parameter is ON.
22. Mixer/Dump Status – This parameter determines whether the Mixer/Dump (combination of the Mixer Motor and Dump Solenoid) of the
selected Hopper is turned ON or OFF. If a Mixer/Dump is ON then dispenses from the selected Hopper will mix and will include water. If a
Mixer/Dump is OFF then dispenses from the selected Hopper will not mix and will not include water. This is a temporary parameter and is
reset to the default setting at “power-on”. The default setting for this parameter is ON
.
23. Displayed Units – This parameter determines whether the displayed units of measure are English or Metric. If the Displayed Units
parameter is set to English then all temperatures are displayed as Degrees Fahrenheit and all volumes are displayed as Fluid Ounces. If
the Displayed Units parameter is set to Metric then all temperatures are displayed as Degrees Celsius and all volumes are displayed as
Milliliters. The default setting for this parameter is English
.
24. Dispense Type – This parameter determines whether the customer is prompted to select a choice of Drink or choice of Soup. If the
Dispense Type is set to Drink then the instructional prompt will read “PLEASE SELECT CHOICE OF DRINK”. If the Dispense Type is set
to Soup then the instructional prompt will read “PLEASE SELECT CHOICE OF SOUP”. The default setting for this parameter is Drink
.