Conair MPA Refrigerator User Manual


 
CHILLER SPI COMMANDS UGH004/0999
APPENDIX B-4
Status, Machine 2
Poll: 0x21 0x44
SPI STATUS WORD
Word BIT position 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
EEprom error SET SET
*
A/D converter error SET SET
*
CJC Error SET SET
*
RAM hardware SET SET
*
ROM checksum SET SET
*
Probe Failure SET SET SET
*
E/M Hi temp safety
*
Prog. Hi temp safety
*
Output monitor failure SET SET
*
Low water pressure
*
High deviation alarm
*
Low deviation alarm
*
Prog. Lo temp safety
*
Pump overload SET SET
*
Refrig. Pressure SET SET
*
Oil Safety SET SET
*
Compressor overload SET SET
*
Freeze Stat
Low water level SET SET
*
Test Mode
*
Phase error
*
NOTES:
*
The SPI I/O list defines the Processing bit as being cleared if the unit is not processing; otherwise it is SET.
Elsewhere on the chart:
If a bit is not shown to be SET, it is cleared.
The System Alarm bit is SET if an alarm is present. It is the logical OR of Process alarm and Machine alarm.
Processing, System Alarm, Process Alarm and Machine Alarm bits are repeated for Process Status, Machine 1
Status and Machine 2 Status.
SPI STATUS WORDS
Open
Open
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Fault, CAL
Fault, Sensor
Alarm, Machine
Alarm, Process
Alarm, System
Processing