11
Connecting Conduit to the Range
NOTE: See page 14 for instructions to connect an appliance
cord to the range.
1. Remove the range electrical access cover from the back of
the range.
2. If using a 4-wire connection, loosen the grounding screw and
remove the neutral to ground jumper link.
3. Remove the nut from the conduit strain relief (not included).
4. Slide the wires and the end of the strain relief into the hole on
the bottom of the range electrical box.
5. Before connecting the wires, slide the strain relief nut over
the wires and thread it onto the conduit strain relief inside the
box. Tighten into place.
6. Connect the white wire to the neutral terminal inside the box.
7. Connect the black wire to the L1 power supply terminal.
8. Connect the red wire to the L2 power supply terminal.
9. If using a 4-wire connection, connect the green wire to the
grounding screw inside the box.
10. Replace the range electrical access cover.
Installation Instructions
Bare wire
connections
Loop and
spade terminal
connections
L1 terminal
L1 terminal
Neutral terminal
Neutral terminal
Jumper link
Link removed
Grounding screw
L2 terminal
L2 terminal
Back wire
Back wire
White wire
White wire
Red wire
Red wire
Green wire
Conduit strain
relief nut
Conduit strain
relief nut
3-Wire Conduit Connection -
Where Local Codes Permit
4-Wire Conduit Connection