Dacor RR30NIFS[-C] Cooktop User Manual


 
7
Installation Specifications
Top View - Downdraft ERV30[15] with Slide-In, Self-Rimming Installation,
3” Side Panels Installed
Top View - Downdraft ERV30[15] with Slide-In, Self-Rimming Installation,
3” Side Panels Removed
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
raised vent opening
27 1/2” (69.9 cm)
30 1/16” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (1.0 cm)
countertop overhang
1” min. (2.6 cm)
to any combustibles
above counter both sides
20 3/8”
(51.8 cm)
to
23 3/8”
(59.4 cm)
20 3/8”
(51.8 cm)
2 5/8” (6.7 cm)
25”
(63.5 cm)
max.
Countertop front
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
raised vent opening
27 1/2” (69.9 cm)
30 1/16” (76.2 cm)*
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (1.0 cm)
countertop overhang
1” min. (2.6 cm)
to any combustibles
above counter both sides
23 3/8”
(59.4 cm)
2 5/8” (6.7 cm)
25”
(63.5 cm)
max.
Countertop front
Cabinet Cutouts for Self-Rimming Installation with Raised Vent (Models RR30NIS and RR30NIFS Only)
* To create a “built-in look” on the front of the
cabinet, this dimension may be changed to 29 1/4”
(74.3 cm), with the width at the notches remaining
30 1/16”. This configuration is only for models
RR30NIS and RR30NIFS with the side panels
behind the door removed.
• Trim kit PN ATKR30SR is required for proper
installation of a raised vent with this range.
• The self-rimming installation of the RR30NI[F]
S range and ERV30[15] raised vent create a
“built-in” look where the range trim overlaps and
rests on the countertop on both sides and the
raised vent trim overlaps the countertop in back.
The ATKR30SR trim kit, installed on the back of
the range, will cover the front of the raised vent
chassis.
• IMPORTANT: When installing the range in this
configuration, ventilation must be provided to allow
for cooling of the ranges internal components. See
diagram, left.
• Observe all vertical cabinet clearances on
page 5.
• A self-rimming countertop configuration is required
for raised vent installation. On installations with a
raised vent, when sliding the range into position, it
will stop when the rear of the control panel or side
panels contact the notches toward the front of the
countertop.
Cut 3” dia. (7.6 cm) holes
at back bottom of cabinet
for ventilation.
Provide ventilation through
cabient both sides,
7 square inches min.
Location may vary.
34 3/4”
(88.3 cm)
to
36 7/8”
(93.7 cm)
(see diagrams)
Countertop
1 5/8 (41.1 cm)
max. thickness