Frymaster EWBS Cooktop User Manual


 
7-18
TROUBLESHOOTING THE BASKET LIFT SYSTEM
If the basket lift motors are activating, but the basket lift fails to raise
or lower, or if its movement is erratic, the probable cause is
jamming or binding of the basket lift rods. Apply a light-weight white
grease (such as Lubriplate
TM
) to the rods. If this does not correct
the problem, check for bent or otherwise damaged rods and links,
and for loose bellcranks.
TROUBLESHOOTING
THE BASKET LIFT
With the basket lift
in the UP position, is 27-33VDC
present at Pin 7 or 9 of IFB 15-pin
connector (0 volts if in DOWN
position)?
Computer has failed.
Replace.
No
Yes
Yes
With the basket lift in the same
position as for the previous check, is
line voltage present at the Common
terminal of the switch?
With the basket lift
in the UP position, is line voltage
present at the NC (lower) terminal of
the microswitch (middle terminal if in
DOWN position)?
IFB has failed.
Replace.
No
Switch has failed.
Replace.
No
Motor has failed.
Replace.
Yes