Page 16
Part # MCOSM06 Rev 1 (11/03/08)
Setting the cook temperature, hold temperature and time
are done in the same manner. Pressing the SET key will
light the TEMP LED. The operator then sets the temperature
by rotating the dial on the controller until the desired
temperature is shown on the display. Pressing the SET key a
second time will light the HOLD LED and allows the operator
to select the desired hold temperature as shown on the
display. Pressing the SET key a third time lights the TIME LED
and allows the operator to select the desired cook time as
shown on the display. Pressing the SET key a fourth time ends
the programming.
Pressing the START/CANCEL key will start the timing cycle.
When the cycle is completed, pressing this key will also cancel
the "DONE" prompt. To cancel a timing cycle in progress press
and hold the START/CANCEL key for 3 seconds.
Core Probe Operation
The Core Probe option (455 Controller Only) is only active
when the core probe is plugged into its connector. To set the
core temperature, rst plug the core probe into its connector.
The display will indicate "100" and the CORE TEMP LED will
be on. The operator then sets the temperature by rotating
the dial on the controller until the desired temperature is
shown on the display. Pressing the SET key stores the core
temperature and starts the cooking process.
To set the oven temperature, press the SET key again. The
TEMP LED will light and the oven temperature can be
set by rotating the dial on the controller until the desired
temperature is displayed. Pressing the SET key again will
light the HOLD LED allowing the operator to set the hold
temperature in the same manner.
NOTE: If the hold temperature is not set, the default hold
temperature is 150°F (66°C) or the last programmed
temperature. (Hold temperature range is 140°F (60°C) to
210°F (99°C).
When the core temperature is reached, the display will sound
and ash "DONE" for 3 seconds. Automatically, the display
will switch to count "UP" the time the oven is on hold.
CHANGING FACTORY SETBACK PROGRAM
To change the factory setback settings, press and hold the
SETBACK key for two seconds. The TEMP LED will light and
a temperature will be displayed (factory preset at 250°F
[121°C]). Set the temperature using the dial, then press the
SET key. The TEMP LED will go out and the TIME LED will light.
Set the time using the dial, then press the SET key. Press the
SET key one more time to exit programming.
Note: To disable the setback function, set the temperature to
250º F (121ºC) and the time to zero..