25
Conversion to LP Gas
This conversion must be performed by a competent
person. After conversion the installation must comply
with the relevant regulations and also the local
electricity supply company requirements. Read the
instructions before converting this appliance.
Failure to convert the appliance correctly could
invalidate any warranty or liability claims and lead to
prosecution.
This instruction must be used in conjunction with
the rest of the appliance instruction, in particular
for information on Standards, cooker positioning,
connection hose suitability etc.
When servicing or replacing gas-carrying components
disconnect from gas before commencing operation and
check appliance is gas sound after completion.
Do not use re-conditioned or unauthorised gas controls.
Disconnect from electricity and gas before servicing.
Check appliance is safe when you have finished.
This appliance is CAT II 2H3+. It is supplied set for G20
natural gas at 20millibar
A conversion kit for LP gas is supplied with the cooker.
Remove pan supports and burner heads.
Burner head
Brass venturi
Burner base
Burner ring
Undo the large brass nuts and remove the brass venturis
and brass rings.
Use a long box spanner to access and remove the
old jets.
Lift up the front of the hotplate top and prop it
up. The burner bases are now accessible - remove
the old jets.
Save the jets removed from the appliance for possible
future use. Fit the new jets, see the table for the correct
type.
If you have lifted up the hotplate then carefully
replace it taking care not to damage or displace the
ignition electrodes or flame safety probes (arrowed)
and replace the rear fixing screws.
Pull off all the control knobs.
Open the oven door & grill door and remove the fixing
screws underneath the control panel.
Remove the 3 fixing screws at the top of the control
panel.
Pull the control panel forward. Rest it on the open grill
door and the open right hand oven door
The tap bypass screw is now accessible. Unscrew the tap
bypass screw.
Using a pair of long nose pliers carefully remove the
bypass screw and fit the correct replacement screw. See
table for correct size. Tighten the screw down.
Repeat for all the burner control taps.
Refi t the control panel.