The following are four examples of the idle mode.
Example 1: AUTOMATIC IDLE - idle temperature is 250’JF
and the idle time is 30 minutes. Control is programmed in eye
idle. If no product is cooked within 30 minutes, control will
automatically select IDLE and regulate at 250OF.
Example 2: AUTOMATIC IDLE - idle temperature is 250°F
and the idle time is 30 minutes. in
idle. Several loads of differen
A
as no more than 30 minutes pass between product selections,
the control will not select idle.
Example 3: AUTOMATIC IDLE - idle temperature is 250°F
and the idle time is 30 minutes. Control is programmed in time
le. A product is selected and several loads are cooked. As
long as a load is cooked within 30 minutes of the last load, the
control will not go into idle. If 30 minutes pass between loads,
the control will automatically select idle.
Example 4: AUTOMATIC IDLE IS NOT PROGRAMMED -
control in manual idle. The control will remain in the product
selected by the operator. Operator must use SELECT
PRODUCT switch to enter idle mode.
The melt mode is used to safely melt solid shortening and can
also be used with liquid shortening. Gradually heating or
melting the shortening greatly extends its life. This is
automatically accomplished in the melt mode by turning the
heat on for 3 seconds and off for 27 seconds. The operator has
the option of entering melt manually with the SELECT
PRODUCT switch or programming automatic melt. Select the
melt mode and program “A” for automatic. At this time also
program the melt temperature. This is the temperature the
control will exit the melt mode and go into the heat mode. It
is recommended to program this temperature at 170OF. After
programming, the control will work as follows: when the unit
is turned on the control checks the pot temperature. If the pot
temperature is below 1 70°F or programmed temperature, the
unit will enter the melt mode. If the pot temperature is above
1700F or programmed temperature, the unit will enter the
programmed 1 st cycle.
Once pot temperature exceeds the programmed melt
temperature the melt mode cannot be entered.