This section provides programming procedures for the
Computron 7000. The operational controls should be read and
understood to become familiar with the control and its
functions. If technical assistance is needed, refer to the toll
free number printed in this manual.
It is recommended to fill out the program worksheet
that was shipped with the unit before programming.
This will result in less confusion when programming
the control.
1. Move the keyswitch to the PROGRAM position.
2. Depress the SELECT PRODUCT switch to the desired
product. The red indicator light will illuminate beside the
particular product you are programming.
3. By depressing the SELECT FUNCTION switch, you pick
the function to program such as time, temperature, etc. The
function you are in will be flashing. Program TIME first.
4. Depress the change switches beneath the digital display
until the desired time is displayed. Example: 11 minutes
- 11:oo.
5. Continue this procedure until you have programmed TIME,
TEMPERATURE, ALARM, and PRESSURE.
An alarm cannot be programmed on the first interval
of any product. Also, your programming temperature
range is from 170° to 390OF.
6. By depressing the SELECT TIME switch you can change
intervals within that function. You may program up to 10
intervals per function.
7. Load compensation, load anticipation, proportional control,
and filter cycle can only be programmed in interval one.
When changing to interval two, only time, temperature,
alarm, and pressure will illuminate in the function display.