While in the melt mode, the first cycle can also be pro
This is the cycle the control will automatically select when in
COOK upon exiting the melt mode. It is programmed
ing the melt mode and depressing the SELECT FU
switch. The green 1st cycle light will flash and the temperature
light in the function display will be on. The left half of the
product display are numbered from top to botto
right half are numbered 7 to 10. Melt and
numbered. However, idle can be selected as th
number one of the product display is desired as first cycle,
program a number one. If number eight of the product display
is desired, program number eight.
An unprogrammed product cycle cannot be selected as
the first cycle.
The one button programming feature is a simple way for the
operator to place Henny Penny’s cooking parameters into the
control’s memory. These programmed cooking cycles are
matched with the menu item cards sent with each unit. To
achieve this one button programming, follow these steps:
1. Turn the COOK/PROGRAM keyswitch to the PROGRAM
position.
2. Depress the TIMER switch. This will put you into the
Special Program Mode. The display will read “SP”.
3. Using the SELECT PRODUCT switch, select the number
7 product (this will be the top right menu item). The display
will read as follows:
Digit
q q q 0
4 3
2
1
Digit 1: Blank’ -’ When the switch under the digit is
depressed it will read INIT for one second then ‘erase all
memory.
Digit 2: Blank - When the switch under the digit is
depressed it will enter all Henny Penny cooking parameters.
Display will read INIT for one second, then HP.
Digit 3: Display will read either F for Fahrenheit degrees
or C for Celcius degrees. By depressing the switch under
the digit, it will toggle from F to C.
Digit ‘4: Display will read either E for electric or 0 for gas
units. By depressing the switch under the digit ‘it will
toggle from E to 0.