Henny Penny OE-30X Fryer User Manual


 
7. Press the set switch and the alarm LED flashes. The left
display shows “AL 1”) the right display shows the alarm
time and can be adjusted with the right Up and Down
Switches.
8. Repeat step 8 for alarms 2,3, and 4.
9. Press and hold the Set Switch to exit program mode, or
continue to second level mode.
The Second Level Program Mode allows the operator to pro-
gram load compensation, load anticipation, proportional control,
filter cycle for the selected product, and the idle parameters.
1. While in the first level mode, push and hold the Set and
Exit Melt Switches for five seconds. The beeper will sound
the left display will show “Slct” (Select) and the right display
will show “Prod” (Product). The Product LED also flashes.
2. Press either the right or left Up and Down Switches to
select a product to program.
3. Press Set Switch and the Other LED flashes. The left display
shows “LdCo,” and the right display shows load compen-
sation setting, and can be adjusted with the right Up and
Down Switches.
4. Press the Set Switch and the Other LED continues to flash.
The left display shows “PC,” the right display shows the
proportional control setting, and can be adjusted with the
right Up and Down Switches.
5. Press the Set Switch and the Other LED continues to flash.
The left display shows. “LdAn,” and the right display shows
load anticipation setting, and can be adjusted with the right
Up and Down Switches.
6. Press the Set Switch and the Other LED continues to flash.
The left display shows “Filtr,” and the right display shows
filter cycles setting, and can be adjusted with the right Up
and Down Switches.
~
7. Press the Set Switch and the Product LED flashes. Press
either right or left Up and Down Switches to select another
product to program. Press and hold the Set Switch to exit the
program mode, or continue on to the third level program
mode.