Henny Penny OE-30X Fryer User Manual


 
Before starting this procedure move MAIN POWER
SWITCH to OFF position. Disconnect main circuit
breaker at the main circuit breaker box and unplug ser-
vice cord from wall receptacle, or electrical shock could
result.
To convert from one type of gas to another the following pro-
cedure may be followed:
1. Turn the gas cock dial to the OFF position.
2. Close the main gas valve and disconnect fryer supply line.
3. Remove gas control valve and burner assembly per sec-
tion 6-9.
4. Remove the burner orifices (24 each), and replace with
orifices in gas conversion kit 16247 - natural to propane
conversion or kit 16248 - propane to natural conversion kit.
5. Remove the pilow orifice and replace with the one from
the kit being installed.
6. Remove the two screws securing the gas valve regulator,
and remove regulator and diaphram, and replace with each
from the kit being installed, per section 6-11.
7. Install converted gas control valve and burner assembly
per section 6-9.
8. Connect the gas supply to the fryer.
9. Be sure the power switch is in the OFF position, gas con-
trol valve in the OFF position.
10. Connect the electrical power to the fryer.
11. Check for gas leak at supply line as per service hints in
this section.
12. Turn the main gas valve on and turn the gas control valve
to the pilot position.