Henny Penny OE-30X Fryer User Manual


 
PILOT
THERMOCOUPLE
The following two procedures must be performed with
the gas supply reconnected and turned on. The service
cord must be plugged into the receptacle and the cir-
cuit breaker on.
1. The pilot burner is preset at the factory. It may require
resetting at the time of installation.
a. Remove the pilot adjustment cap.
b. Use a small flat screwdriver and rotate the adjustment
screw counterclockwise to increase the size of the flame.
Rotate clockwise the adjustment screw to decrease the
size of the fla.me.
The flame should be set high enough to surround the
top of the thermocouple.
1. The pressure regulator is preset at the factory. It may re-
quire resetting at the time of installation.
a. Turn gas cock dial to OFF position.
b. Attach a manometer to the gas valve at the “Pressure
Tap.”
e. Turn gas cock dial to “PILOT,” light, and turn to ON.
d. Remove the regulator adjustment screw cap.
e. Rotate the adjustment screw counterclockwise to in-
crease the column indicated on the manometer or rotate
clockwise to lower the column indicated.
f. Turn gas cock dial to OFF and remove manometer.
g. Replace the regulator adjustment screw cap.
h. Turn gas cock dial to PILOT and relight. Leak test with.
soap and water solution.
Natural gas regulator is factory preset at 3% inches
water column.
Propane gas regulator is factory preset at 10.0 inches
water column.