The gas control valve regulates the flow of gas to the pilot
and the main burner. The valve consists of: gas regulator,
magnetic plug, pilot gas tube, gas cock dial, pilot adjustment
cap and screw, gas outlet and inlet ports, thermocouple con-
nector, and electrical connection. The gas valve also has a dial
reference point. - OFF/PILOT/ON.
The components of the gas valve can be serviced without
removing the complete valve from the fryer.
If converting from natural gas to propane gas or from
propane gas to natural gas, conversion must be done
by a qualified technician.
To avoid injury or property damage, before starting
this procedure, move the MAIN POWER switch to the
OFF position. Disconnect the main circuit breaker at
the circuit breaker box or unplug the service cord at
the wall receptacle. Turn off the main gas supply to
the frypot to be worked on, or possible explosion could
result.
If the gas control valve must be replaced, remove per
paragraph 6-9.
erat
1. Depress the gas cock dial and turn to the OFF position.
2. Remove control panel per section 6-3.
3. Label and remove the gas valve wires from terminal block.