eset”
4. To replace the pump and motor assembly, insure the main
power has been removed from the fryer.
Before starting this procedure move MAIN POWER
SWITCH to OFF position. Disconnect main circuit
breaker at the main circuit breaker box and unplug ser-
vice cord from wall receptacle, or electrical shock could
result.
5. Remove the cover from the junction box and remove the
wire nuts attaching wires leading into the flexible conduit
going to the motor.
6. Loosen the two screws securing the flexible conduit to the
conduit connector.
7. Remove tubing to the pump.
8. Remove hardware attaching the motor to the motor base
bracket and remove motor and pump assembly.
The filter pump motor is equipped with a manual reset button
in the event the motor’s thermal protector actuates. This reset
button is located on the rear of the motor. Wait approximate-
ly 5 minutes before attempting to reset this protector device.
To prevent burns caused by splashing shortening, the
unit’s main power switch must be in the OFF position
before resetting the filter pump motor’s manual reset
protection device.