Henny Penny OE-30X Fryer User Manual


 
ova
1. If the pump needs to be replaced, loosen one inch nuts from
the outflow and inflow lines. Then remove the two bolts
holding the pump to the motor with a l/2 inch wrench.
2. The shaft seal should remain on the motor shaft, or if leak-
ing, could be replaced at this time.
3. To replace the pump, remove the four allen screws, front
plate, rotor, and rollers from pump. Place the pump onto
the shaft and against the shaft seal. Place the two l/2 inch
bolts through the pump and into the motor and tighten.
Then replace the rotor, rollers, front plate and tighten the
allen screws.
When removing a pump from a motor, note the posi-
tions of the INLET and OUTLET parts. Installation
of the pump on the motor in any other position could
cause damage to the fryer. There is an indicator on the
side of the two halves of the pump, this mark must be
together and face to the front of the fryer.