Hoshizaki dcm-75ibah Ice Maker User Manual


 
56
Note: We reserve the right to make changes in specications and design without prior
notice.
AC SUPPLY VOLTAGE 115/60/1
COMPRESSOR 115 V 77 LRA 11.0 RLA
GEAR MOTOR 115 V 3.0 FLA 1/4 HP
AGITATING MOTOR 120 V 1.8 FLA (TOTAL) 110 W (TOTAL)
DISPENSING MOTOR 115 V 0.9 FLA 55 W
OTHER 115 V 0.6 A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lb./day (kg/day) 70 *800 (363) 779 (353) 758 (344)
Reference without *marks 80 738 (335) 719 (326) 700 (317)
90 681 (309) *685 (311) 646 (293)
100 629 (285) 612 (278) *563 (255)
SHAPE OF ICE Cubelet
ICE HARDNESS FACTOR 90% (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY 95 lb.
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lb.) 1281 (4.77) 1274 (3.86)
POTABLE WATER 82 (12.0) 96 (12.0)
WATER-COOLED CONDENSER 517 (76) 380 (47)
gal./24HR (gal./100 lb.)
EXTERIOR DIMENSIONS (WxDxH) 34-1/16" x 28-1/2" x 48-1/16" (865 x 723 x 1221 mm) (No legs)
EXTERIOR FINISH Stainless Steel; Galvanized Steel (Rear)
WEIGHT Net 300 lb. (136 kg), Shipping 345 lb. (156 kg)
CONNECTIONS - ELECTRIC Permanent Connection
- WATER SUPPLY Inlet 1/2" FPT Condenser Inlet 1/2" FPT
- DRAIN Drip Tray Drain Outlet 3/4" FPT Condenser Outlet 3/8" FPT
Storage Bin Drain Outlet 3/4" FPT
ICE MAKING SYSTEM Auger Type
HARVESTING SYSTEM Direct Driven Auger (1/4 HP Gear Motor)
ICE MAKING WATER CONTROL Float Switch
DISPENSER CONTROL SYSTEM Push Button
COOLING WATER CONTROL Water Regulating Valve
BIN CONTROL SYSTEM Mechanical Bin Control and Timer
COMPRESSOR Hermetic, Model RST61C1E-CFA-202
CONDENSER Water Cooled, Tube in Tube Type
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Thermostatic Expansion Valve
REFRIGERANT CHARGE R-404A, 1 lb. 6 oz. (624 g)
DESIGN PRESSURE High 460 PSIG, Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION High Voltage Power Protect Relay
COMPRESSOR PROTECTION Auto-Reset Internal Protector
GEAR MOTOR PROTECTION Auto-Reset Internal Protector and Fuse (3A)
REFRIGERANT CIRCUIT PROTECTION Auto-Reset High Pressure Switch
LOW WATER PROTECTION Float Switch and Timer
ACCESSORIES - SUPPLIED Spare Fuse (2-3A), Legs
- OPTIONAL HS-5003, Apron kit when drip tray removed
OPERATING CONDITIONS VOLTAGE RANGE 104-127 VAC
AMBIENT TEMP. 45-100° F
WATER SUPPLY TEMP. 45-90° F
WATER SUPPLY PRESSURE 10-113 PSIG
ENG F-013.0.1196