6) Disconnect the rinse pump motor wiring at the closed end connectors.
7) Remove the nut from the exible tube at the rinse pump motor discharge outlet and
the bolts securing the bracket to the unit base.
8) Remove the band from the pipe joint of the booster tank discharge pipe behind the
rinse pump motor and the exible tube at the rinse pump motor suction inlet. Pull the
end of exible tube out of the booster tank discharge pipe.
Note: Use a hand mirror for easy removal.
9) Remove the rinse pump motor together with the bracket. Remove the band from the
pipe joint of the rinse pump motor suction inlet pipe and exible tube to release the
exible tube.
10) Unscrew the bracket, and remove the rinse pump motor.
11) To replace, reverse the above procedure.
Note:
1. Be careful not to mix up the wire colors. Miswiring will cause reversal of the pump
motor, resulting in improper operation.
2. Cover the connections with the original plastic sheet cover and secure with a nylon
tie. Make sure the connections are situated so that water and condensation cannot
reach the connections.
3. Be sure to use new O-rings and gaskets. Be careful of the direction of the
U-packing for the suction inlet pipe.
12) Make a trial run, and check for water leaks.