Hoshizaki JWE-24000CUA-L-25B Dishwasher User Manual


 
1
I. Speci cations
A. Speci cation Sheet
1. JWE-2400CUA-L-25B
DISHWASHER SIDE BOOSTER SIDE
3 phase 3-wire 208-230V/60Hz (±10%) /
2 power supply lines
208V : 18.4kVA(51.1A)
230V : 22.1kVA(55.5A)
208V : 20.6kVA(57.2A)
230V : 25.3kVA(63.5A)
Max Running 51.2A
Rated Motor 9.0A
Max Running 63.3A
26.0A
Max 19.86kW
Rated Motor 3.06kW
Power Factor 84%
Max 25.20kW
AC SUPPLY VOLTAGE
POWER SUPPLY CAPACITY
AMPERAGE
STARTING AMPERAGE
ELECTRICAL COMSUMPTION
HEATER
16.80kW(230V) 25.20kW(230V)
RACK SIZE
NUMBER OF LARGE DISHES / RACK
CAPACITY
WATER COMSUMPTION
PASSING HEIGHT
DIRECTION OF OPERATION
19-3/4" × 19-3/4"(500 × 500mm)
16 plates (9.1” DIA)
240/200/160racks/hour
adjustable in 3 steps (rotary switch)
114Gal/hour(432L/hour), 0.48 Gal/rack(1.8L/rack) - at 240rack/hour
20.5" (520mm)
Left to Right
OUTSIDE DIMENSIONS
EXTERIOR
DOOR
LEG
W57.3" × D27.6" × H58.1" (W1,455 × D700 × H1,475mm)
Stainless Steel
Vertically Sliding Service Panel(Opening:W25.6" × H18.9")
Stainless Steel Adjustable 9.4" - 11.0"
Upper and Lower Fixed Spray
Wash 1HP x 2, Rinse 0.134HP
Draw Out Overflow Pipe, Overflow Drain
Rack Detection (Wash/Rinse)
Residual Heat Drying
Filter Collection
Not Provided
Wash Water Temperature / Rinse Water Temperature (selectable by switch)
Ready, Auto Fill, Wash, Error Code
27.2Gal (103L)
Automatic Hot Water Supply by
Microprocessor Control
Wash: 160ºF (71ºC) min.
Thermistor Control: 163ºF(73
C) – 168
㩷㪝
(76
C)
12.4Gal (47L)
Automatic Hot Water Supply by
Water Valve
Rinse: 180ºF (82ºC) min.
Thermistor Control: 182ºF(83ºC)-185ºF (85ºC)
WASH SYSTEM ,RINSE SYSTEM
PUMP
DRAIN SYSTEM
START
DRY SYSTEM
REFUSE DISPOSAL
DETERGENT
DISPLAY
TANK CAPACITY
HOT WATER SUPPLY
TEMPERATURE CONTROL
CONNECTION – WATER SUPPLY
– DRAIN
Inlet: 3/4"FPT
Outlet: 1-1/2"MPT
CONTROL Microprocessor control
Water Level Switch,
Bimetal Thermostat (Manual - Reset),
Thermistor (Auto - Reset)
Float Switch,
Bimetal Thermostat (Manual - Reset),
Thermistor (Auto - Reset)
BOIL – DRY PROTECTION
SAFETY SYSTEM
Service Panel Switch, Emergency Stop by Microprocessor Control
Table Limit Switch, Emergency Stop Button, Conveyor Overload Protector
WEIGHT Net 430lb (195kg) / Gross 584lb (265kg)
PACKAGE
Carton + Crate
W62.6"×D32.9"×H65.9" (W1,590mm ×D 835mm × 1,675mm)
CERTIFICATION
NSF ANSI-3, ETL, cETL, Energy Star
ACCESSORIES-SUPPLIED
Universal rack (19-3/4" x 19-3/4"), Instruction manual, Installation manual
Maintenance sheet, Curtain(L), Curtain(S) x 2, Shaft - curtain(L), Shaft - curtain (S) x 2
Guard(L), Guard(R), Hook - Drain, Table limit Switch, Upper wash spray arm,
Operation box assembly, Cable cover, Inlet water strainer & Packing
ACCESSORIES-REQUIRED Universal rack (addition), Ventilation hoods x 2, Drain Tempering Kit
OPERATION CONDITIONS
Ambient Temperature: 41 - 95ºF (5ºC - 35ºC), Voltage Range: Rated Voltage ±10%
Recommends Water Hardness : 4gpg (grains per gallon) (68.5ppm) or less
Water Supply Temperature: 110 - 167ºF (43ºC - 75ºC) ( Recommends 140 ºF (60ºC))
Water Supply Pressure (Gauge Static Pressure): 10 - 70PSIG (0.07 - 0.48 MPa)
Exhaust Requirements : 200CFM(Entrance End),400CFM(Discharge End)
* The rated properties are based on measurements at ambient temperature of 86ºF (30ºC) according to the Technical
Requirements for Electrical Appliances.
* We reserve the right to make changes in specifications and design without prior to notice.