Cornelius 1550 Beverage Dispenser User Manual


 
56900024613
An excessive accumulation of dust, lint, and grease on the condenser coil will restrict air flow through the coil
which will decrease cooling efficiency of the Unit. The Unit condenser coil should be periodically cleaned to
maintain cooling efficiency of the Unit. Contact a qualified Service Person to clean the Unit condenser coil.
CHECKING ICE WATER BATH
A gurgle heard from the Unit while it is operating, indicates the water level in the water tank is low and more
water should be added to the tank. Contact a qualified Service Person to replenish the water tank water supply
and if necessary, also clean the water tank.
CLEANING AND SANITIZING
DAILY CLEANING
The Unit should be cleaned daily as instructed SERVICE AND MAINTENANCE section of this manual.
SANITIZING BEER SYSTEMS
The beer systems (tappers, beer lines, Unit beer cooling coils, and the beer faucets) should be completely sani-
tized at least every two weeks as instructed in SERVICE AND MAINTENANCE section of this manual.
REPLENISHING CO
2
SUPPLY
WARNING: CO
2
displaces oxygen. Strict attention must be observed in the prevention of
CO
2
(carbon dioxide) gas leaks in the entire CO
2
and soft drink system. If a CO
2
gas leak is
suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
2
gas will experience
tremors which are followed rapidly by loss of consciousness and suffocation.
NOTE: When indicator on CO
2
cylinder regulator assembly 1800 psi gage is in shaded (‘‘change CO
2
cylinder’’) portion of dial, CO
2
cylinder is almost empty and should be replaced.
The CO
2
supply should be checked daily and if necessary, replenished as instructed.
REPLENISHING BEER SUPPLY
The beer supply should be checked periodically and if necessary, replenished as instructed.
CLEANING CO
2
SYSTEM GAS CHECK VALVES
(see Figure 2)
The CO
2
gas check must be inspected and serviced as instructed at least once a year under normal conditions
and after any servicing or disruption of the CO
2
system.