B. Remove water fill hole plug from evapora-
tor tank cover.
C. Fill evaporator tank until water starts flow-
ing from overflow tube. USE LOW--MINER-
AL--CONTENT WATER WHERE A LOCAL
WATER PROBLEM EXISTS.
D. Install plug in water fill hole in evaporator
tank cover.
E. Install plug in end of evaporator tank over-
flow tube after full ice bank has been
formed.
4. Install cover on unit and secure with four
screws.
5. Flip unit power switch (see Figure 3) to ‘‘OFF’’
(down) position.
WARNING: Unit must be electrically
grounded to prevent possible fatal
electrical shock or serious injury to
operator. Unit power cord is equipped with a
three--prong plug. If a three--hole (grounded)
electrical outlet is not available, use an
approved method to ground unit.
6. Plug unit power cord into a properly grounded
electrical outlet.
7. Flip unit power switch to ‘‘ON’’ (up) position.
8. With unit power switch in ‘‘ON’’ position, make
sure compressor, condenser fan motor, and agi-
tator motor start to begin forming an ice bank.
When full ice bank is formed, compressor and
condenser fan motor will stop but agitator motor
will continue to operate circulating ice water
bath in evaporator tank.
PREPARING UNIT FOR OPERATION
1. Adjust product tanks CO
2
regulators as
instructed.
2. Connect product tanks into systems. Check for
leaks and tighten loose connections.
UNIT OPERATION
1. Dispense from dispensing valve until air is bled
from system and product is dispensed.
2. Repeat step 1 preceding to purge air from re-
maining systems.
3. Adjust dispensed product flow rate as
instructed.