Cornelius 750 Pre-Mix Beverage Dispenser User Manual


 
23 189159000
Trouble RemedyProbable Cause
NOTE: If overload protector cuts out compressor, condenser fan motor
will continue to run; otherwise; troubleshooting condenser fan motor
problems is same as for COMPRESSOR DOES NOT OPERATE
paragraph plus the following:
CONDENSER FAN MOTOR
NOT OPERATING.
A. Jumper cord loose or
disconnected from motor or
terminal block. Broken wire is
cord.
A. Tighten connections or replace
cord.
B. Fan blade obstructed. B. Remove obstructions.
C. Inoperative condenser fan
motor.
C. Replace condenser fan motor.
AGITATOR MOTOR NOT
OPERATING.
A. Unit power cord or agitator
motor power cord
disconnected or unit power
switch in OFF position.
A. Plug in power cords or place unit
power switch in ON position.
B. No power source (blown fuse
or tripped circuit breaker).
B. Replace fuse or reset circuit
breaker. (Note: Fuse is not part of
unit).
C. Agitator motor propeller
obstructed.
C. Remove obstructions.
D. Low voltage. D. Voltage must be at least 103 volts
(115 VAC model or 208 volts (230
VAC model) at compressor
terminals when compressor is
trying to start.
E. Loose, disconnected, or
broken wiring.
E. Tighten connections or replace
broken wiring.
F. Inoperative agitator motor. F. Replace agitator motor as
instructed.