REMOVAL AND REPLACEMENT OF AGITATORS
To Remove Agitators For Cleaning (300 shown)
NOTE: All other models have only one agitation Assembly.
FIGURE 14
1. Lift agitator and disc from unit.
2. Remove O-Ring starting at notch. Warm the O-Ring with water to ease removal.
3. Lift the plastic agitator disc off of the stainless-steel agitator.
4. Replace by reversing steps.
NOTE: Refer to Sanitize Procedure in the Owners Instruction for complete cleaning and sanitiz-
ing
instructions.
LEFT HAND
AGITATOR
O–RING
FRONT (VALVE SIDE) VIEW FROM TOP OF DISPENSER
RIGHT HAND AGITATOR
WITH HOLE IN UPRIGHT
COUNTERCLOCKWISE
ROTATION
CLOCKWISE
ROTATION