MAINTENANCE/ADJUSTMENT PROCEDURES
THERMOSTAT ALTITUDE ADJUSTMENTS
IMPORTANT: Adjust the bin thermostat setting only if storage hopper over fill is a problem.
BIN THERMOSTAT
1. Open the hinged service door.
2. The adjustment screw is located below the Flush”switch on the left side of the electrical box.
3. For altitudes up to 6,000 feet, turn the adjustment screw COUNTERCLOCKWISE
as follows:
ELEVATION (FE ET) COUNTERCLOCKWISE TURN
2,000 1/13
4,000 1/6
6,000 1/4
4. For altitudes above 6,000 f eet, consult the factory.
ICE THICKNESS ADJUSTMENT
W ARNING: Do no t adjust ice thickness probe unless all other problem causes have been
evaluated.
1. Open the hinged service door on t he upper left side panel and remove the ice drop and hopper covers.
2. Collect and weigh the ice produced during the harvest cycle. The amount of ice harvested should weigh
approximately 3 pounds. Use t he following procedure to adjust t he probe to obtain this weight. (A clockwise
adjustment will reduce the harvest weight while counterclockwise turns will increase the amount.)
CAUTION: Do not turn the screw on the end of the probe. Rotate the plastic probe body
only using a 3/8 in ch open end wrench. Make adjustments in 1/8 in ch turn increments.
A. Place the “Stop /Run”switch in the “Sto p”position. (If unit is in the ic e making cycle, stop the unit at
th e en d of the harvest cycle).
B. Access to the probe is obtained by removing the rear service panel. (For units without beverage fau-
cets, t he probe can be adjusted from the front by removing the lower front panel if rear access is
blocked).
C. Adjust the probe.
D. Place the Stop/Run”switch in t he Run”position.
E. Collect and weigh the ice harvested. Repeat step A through E as necessary to obtain the required
amount of ice.
3. In m a king an initial adjustment (f or example, if t h e probe has been removed and replaced for any reason),
turn probe clockwise until it just touches t he evaporator coil (a slight back pressure will be felt). Turn probe
counterclockwise 2-1/2 turns. Follow procedure in step 2 to obtain the required ice harvest weight.