Cornelius SID650A/80-BC Ice Maker User Manual


 
3
91704
IMPORTANT: To ensure proper ice maker operation and also to reduce the frequency of water-rel ated
service problems, a water filter should be installed. Remcor recommends the use of IMI Cornelius filter,
model number 81COR01PS.
For specific recommendations on these filter systems for you r local conditions, consult with a distribut or in your
area or contact the filter m anufacturer.
Connect two (2) 3/4
IPS (or equal) drain lines to t he 3/4 threaded drain connections at the lower rear of the
unit. These lines must pitch downward
to an open drain and must contain no traps or improper drainage
will result.
NOTE: In areas where consistently warm water temperatures are encountered, the use of a Remcor Pre-
Cooler in the water line is recommended to maximize the ice production of this unit. Contact Remcor
for more information on this product.
3.
Electrical
A 4 x 2 junction box is located at the rear of the unit for the supply hook-up. Connect the ice maker to its
own individual circuit per the national electric code and local code. See SPECIFICATIONS f or ampacity
and fuse size.
IMPO RTANT: The wire size must be adequate for the ampacity rating, and the supply voltage must be
within a range of ± 10% for proper ice maker operation.
NOTE:Theunitsrequirea2wire
system plus earth ground for proper operations.
220V
1 PHASE
60 HERTZ
SUPPLY CONDUIT
BROWN (HOT)
BLUE (NEUTRAL)
GREEN (GROUND)
REAR VIEW -- BOTTOM SECTION SERVICE PANEL REMOVED
FIGURE 1. ELE CTRICAL WIRING INSTALLATION INSTRUCTIONS