Cornelius SID650A/80-BC Ice Maker User Manual


 
31 91704
CLEANING/REPLACE THE FILTER
1. Remove the filter from the cabinet panel by sliding it forward toward the front of t he unit.
2. Wash the filter in a solution of warm water and a mild
detergent. Do not use caustic detergents as they
may attack the aluminum filter elements.
3. Dry filter thoroughly.
4. For m aximum effectiveness, reactivate the filter with an air f ilter coating (see Parts List, Miscellaneous
Components).
CLEANING THE CONDENSER
Air-Cooled Units.
1. Disconnect power to t he unit.
2. Remove the upper front and right side panel.
3. Remove all dirt/foreign material built up from the condenser fins (fan side). Be careful not to damage the
fins. It is recommended that a power vacuum cleaner with a crevice”tool att achment be used.
CLEARING EVAPORATOR FREEZE-UP
W ARNING: To preven t possi ble inj ury, do not place fingers or hand into ice maker no zzle or
hopper with power applied to the unit.
1. Open the hinged service door on t he upper left side panel.
2. Place the Stop/ Run”switch in the “Stop”position.
3. Close the water supply valve t o the ice m aker.
4. Remove the ice drop and hopper covers.
5. Depress t he Flush”switch push but ton and drain the evaporator.
6. Pour hot water into the evaporator ice exit opening. It will be necessary to use either a funnel or a container
with a spout. Fill the evaporator completely.
7. Drain the evaporator. Repeat steps 5 and 6 as required to ensure that all the ice in the evaporator is
melted.
8. Open the water supply valve. Depress the fill switch and refill evaporator.
9. Replace the ice drop and hopper covers.
10. Consult TROUBLES HOOTING GUIDE to det ermine cause of freeze-up before putting unit back in service.