To Adjust the Thermostat:
Electric Shock Hazard.To prevent electrical shock, disconnect
power before removing access cover to service the thermostat.
Scalding Hazard.Do not allow water to boil. May result in severe
burns.
On the front of the tank there is an access panel. Unscrew
the holding screw and locate the temperature control dial.
The thermostat is pre-set at the factory to approximately
190˚ F. If a thermostat adjustment is required, turn knob
clockwise 1/2 dial mark to increase the water temperature
and counterclockwise 1/2 dial mark to decrease the water
temperature.
10. Test the Water Connection
Test the water connection to see if it is watertight. If it is not, relieve water pressure
by turning off the water supply,and adjust or tighten fittings as necessary. Note
that water must flow from the dispenser faucet to test all connections.
Note: Ensure both hot and cold side are checked on the HC model.
DO NOT PLUG IN THE TANK.
11. Plug in the Tank
Once the tank is plugged in, it will take between 10 and 15 minutes for the water
to reach its target temperature. During the heating cycle, you can expect to hear
gurgling or hissing sounds within the tank.This is normal.
Electric Shock Hazard. This appliance must be properly grounded. Using an
ungrounded appliance can result in serious injury or death from electric shock.
Improper connection of the equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician if you are in doubt as to
whether the outlet is properly grounded. Do not modify the plug provided with
the appliance. If it will not fit in the outlet, have the proper outlet installed by a
qualified electrician.
The Installation, page 5 of 5