Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
18 16026923
© 2006 Maytag Services
Control Component Test Procedure Results
Switch membrane assembly
NOTE: To avoid equipment
damage, use caution when
checking electronic control
circuitry.
JGS8860BD*
Closed circuitry resistance
(defined as continuity): 2000 Max
Pins 1 & 7 are shorted together for control
configuration purposes
Detail B
See Detail B
Trace # 1
Latch
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Bake
Broil
Convect
Clean
Favorites
Rapid Preheat
Warming Drawer
More Options
Setup
ATM 1
ATM 2
Back
Enter
Timer 1
Timer 2
Oven Light
Trace
2 & 7
2 & 8
2 & 9
2 & 10
2 & 11
2 & 12
3 & 6
3 & 7
3 & 8
2 & 6
4 & 9
4 & 10
4 & 11
5 & 9
5 & 7
4 & 12
5 & 10
5 & 11
5 & 8
5 & 6
4 & 6
4 & 7
3 & 9
3 & 10
3 & 11
3 & 12
4 & 8
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Switch membrane assembly
NOTE: To avoid equipment
damage, use caution when
checking electronic control
circuitry.
JGS9900BD*
Closed circuitry resistance
(defined as continuity): 2000 Max
Pins 1 & 10 are shorted together for control
configuration purposes
Detail B
See Detail B
Trace # 1
Latch
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Bake
Broil
Convect
Clean
Favorites
Rapid Preheat
Vent Fan
More Options
Setup
ATM 1
ATM 2
Back
Enter
Timer 1
Timer 2
Oven Light
Trace
2 & 7
2 & 8
2 & 9
2 & 10
2 & 11
2 & 12
3 & 6
3 & 7
3 & 8
2 & 6
4 & 9
4 & 10
4 & 11
5 & 9
5 & 7
4 & 12
5 & 10
5 & 11
5 & 8
5 & 6
4 & 6
4 & 7
3 & 9
3 & 10
3 & 11
3 & 12
4 & 8
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
COOLING FAN TEMPERATURES
MODE FAN ON TEMP F (C) FAN OFF TEMP F (C)
Bake 350 (177) 300 (149)
Broil
Six (6) minute delay
after cycle started
225 (107)
Clean
Six (6) minute delay
after cycle started
225 (107)