Blue
Gray
Red
Brown Red
POWER
J 5J 4J 3 J 1
J 6
LOCKED ROTOR
To T/T display
POTENTIOMETER
Max.
Conveyor
Speed Adj.
Min.
Conveyor
Speed Adj.
TIME/TEMP
Black to #4
White to #7
ON
12345
CURRENT SENSE
DO NOT ADJUST
Heat Sink
MOTOR
1. With power off, the five (5) dip switches located on the conveyor control (see drawing above ) should be set as
below.
DIP SWITCHES FOR 50 SEC. TO 30 MIN. TIMES
CONTROL 1 2 3 4 5
SWITCH POSITION OFF OFF ON OFF OFF
DIP SWITCHES FOR 23 SEC. TO 30 MIN. TIMES
CONTROL 1 2 3 4 5
SWITCH POSITION OFF ON OFF OFF OFF
2. With power off, the ten (10) dip switches located on rear of Time/Temp Display (see drawing on page D15)
should be set as below.
NOTE: For time/temp displays using a thermister (2 yellow wires on Terminals 9 & 10), set the dip switches as
follows:
FOR 50 SEC TO 30 MIN CONVEYOR TIMES
DISPLAY 1 2 3 4 5 6 7 8 9 10
SWITCH POSITION OFF * * ON ON OFF OFF ON OFF ON
Impinger II - 1100 Series Service Manual - International 65