Miele 09 885 260 Ventilation Hood User Manual


 
Cleaning and care
32
Resetting the grease filter operating
hours counter
After cleaning, the operating hours
counter needs to be re-set.
Whilst the fan is switched on, press
the operating hours control  for
approx. 3 seconds, until only the 1 is
flashing.
The grease filter symbol goes out.
If you want to clean the grease filter(s)
before the operating hours counter has
reached its maximum,
Press the operating hours control
 for approx. 6 seconds, until only
the 1 is flashing.
Charcoal filters
With recirculation mode, two charcoal
filters must be fitted in addition to the
grease filters. These are designed to
absorb cooking odours.
Charcoal filters can be obtained from
your Miele dealer or via the internet at
www.miele-shop.com. See end of this
booklet for contact details, and
"Technical data" for type and reference
number.
Fitting/replacing charcoal filters
The slots for the charcoal filters are
located above above the grease filters.
Remove the cover. It is held in place
by magnets.
Take the charcoal filters out of their
packaging.
Insert the charcoal filters in the slots.
Replace the cover.
When fitting for the first time, activate
the operating hours counter (see
"Operation").